All Categories
    Menu Close

    4 in1 pH Pen, pH/EC/TDS/Temp

    Good price 4 in1 pH pen allows for simultaneous detection of pH, EC, TDS, temperature parameters, displayed on a large screen. Test range of 0~14pH, 0~9999us/cm, 0~9999ppm, 0~60℃(32~140℉). With high precision and automatic temperature compensation, this ph instrument has accurate measurements. The smart calibration system simplifies the calibration process, while the ability to switch between Celsius and Fahrenheit enhances flexibility.
    SKU: T-PHM-MPH300
    $63.68
    i h
    Free shipping
    Delivery date: 6-12 days
    Overview

    The 4-in-1 pH pen offers multiple parameters for simultaneous detection, all displayed on a large screen for easy reading. It features high precision with automatic temperature compensation and smart calibration. Users can switch between Celsius and Fahrenheit and lock readings with one click. The pen type ph meter is IP65 protected, has a power display, and conserves energy with a 5-minute automatic shutdown feature, making it both practical and efficient for water quality testing.

    Specification

    Model T-GWQ-MPH300
    Measure parameters pH, EC, TDS, Temperature
    Range 0~14pH, 0~9999us/cm, 0~9999ppm, 0~60℃(32~140℉)
    Accuracy ±0.05pH, ±2%μs/cm, ±2%ppm
    Operating temperature 0 ~ 60°C (32~140°F)
    Temperature compensation Automatic temperature compensation
    Calibration method pH: three-point calibration, EC/TDS: single-point calibration
    Automatic shut-down 5 minutes automatic shutdown
    Power Supply Battery powered (4*1.5V, LR44)
    Size 183.5*40*20mm
    Weight 93g

    Feature

    ph pen feature

    • Large LCD Display: Equipped with a clear liquid crystal display (LCD) for easy reading, even in dark environments. The screen simultaneously shows pH values and water temperature data, ensuring accurate and timely monitoring.
    • Four-in-One Functionality: The device integrates four testing functions: TDS (Total Dissolved Solids), EC (Electrical Conductivity), pH, and Temperature, making it highly versatile for water quality analysis.
    • Smart Imported Chip: Powered by an intelligent imported chip for high precision measurements, ensuring long-lasting durability and stable performance in various testing conditions.
    • High-Sensitivity Glass Electrode: Features a high-sensitivity glass electrode with a detachable probe design, which allows for easy replacement and maintenance, ensuring continuous high performance.
    • High-Capacity Button Battery: Utilizes four high-capacity button batteries that provide extended usage time, making it convenient for users to replace as needed for uninterrupted functionality.
    • Simple Testing Method: User-friendly interface and operation method make this device suitable for all ages, allowing anyone to easily test water quality at any time and monitor its health attributes.

    Detail

    ph pen detail

    Application

    ph pen application

    Tips: Why Is It Necessary to Calibrate the Electrode Regularly?

    After a period of use, the pH electrode may show errors in measurement results. To obtain accurate measurements, calibration is required regularly, especially under stringent environmental and precision requirements.

    Calibration Using Standard Buffer Solution:

    1. Pour the appropriate amounts of the 6.86, 4.01 (at 25°C) standard buffer solutions into separate clean and dry beakers.
    2. To ensure accurate calibration, use two beakers for each type of buffer solution: one for washing the electrode and the other for holding the buffer solution. This helps minimize contamination of the buffer solution.
    3. Press the "ON/OFF" button to power on the device.
    4. Place the electrode into the standard buffer solution, gently stir, and wait for the readings to stabilize. Press the "CAL" button, and the instrument will automatically enter calibration mode, with the reading fluctuating until the display matches the calibration value. Once stabilized, calibration is complete.

    Calibration Using Pure Water (pH 7 Value):

    1. To ensure accurate calibration, use two beakers: one for rinsing the electrode with pure water and the other for holding the pure water solution.
    2. Press the "ON/OFF" button to power on the device.
    3. For calibration, immerse the electrode in pure water, press and hold the "TCAL" button. When 6.86 flashes on the screen, the device will automatically enter calibration mode. The number will stabilize after the automatic process completes, and the display will show 6.86, indicating successful calibration.
    0.0 0
    Write your own review Close
    *
    *