All Categories
    Menu Close

    Single Phase DIN Rail Digital Energy Meter, LCD Display

    Low cost single phase DIN rail digital energy meter with LCD display, DIN rail mounted, with grade 1 accuracy for active energy, 2P, direct connection can up to 100A. With 4-digit LCD display, RS485 communication interface, support for Modbus-RTU protocol, 35mm DIN rail mounting, it is very easy to install.
    SKU: T-DEM-2P
    $225.69
    i h
    Free shipping
    Delivery date: 6-12 days
    Overview

    Single phase DIN rail energy meter with 4-digit LCD display, low voltage current transformer (LVCT) connection is more compact, with lower installation cost and safer environment. The single-phase energy meter adopts intelligent metering chip, with high accuracy, small error, and no adjustment required for long-term use. The operation interface of the energy meter is simple and easy to use. It combines excellent performance and easy installation to provide cost-effective power monitoring applications.

    Specification

    Model T-DDS1946-2P
    Accuracy Grade Grade-1 accuracy for active energy
    Phase Single phase (2 wire)
    Number of Poles 2P
    Rated Voltage 230V
    Current Direct Input 5(100)A
    Frequency 50/60Hz
    Display Mode LCD display
    Display Digits 4
    Energy Pulse 1 energy pulse output, pulse width (80±20%) ms
    Measurement Range Voltage/Current/Active power/Power factor/Frequency
    Communication Interface RS485, Modbus-RTU protocol, 2 wire, up to 9600bps
    IP Protection IP54 (panel) /IP20 (case)
    Certificate CE/ ISO/ MID
    Warranty Period 12 months
    Dimension 36*63*90mm
    Weight 1.0kg
    Installation Din rail 35mm
    Work Temperature -10℃~55℃
    Storage Temperature -25℃~70℃

    Dimension (unit=mm)

    single phase digital energy meter din rail mounted dimension

    Wiring

    single phase digital energy meter din rail mounted wiring

    Tips: What should I pay attention to when installing an energy meter?

    • Choose a suitable location: Install in a dry, well-ventilated place without corrosive gases, avoid direct sunlight and high temperature. Keep away from flammable and explosive items, and ensure that there is no strong magnetic field or strong electric field interference around.
    • Wiring specifications: Use standard wires, and the cross-sectional area should meet the load requirements. Ensure that the wiring terminals are tight to avoid looseness or poor contact.
    • Debugging and inspection: Confirm that the wiring is correct, without short circuit or open circuit. Observe whether the energy meter is running normally and whether the display is clear. Use professional equipment to detect the error of the energy meter to ensure that it meets the standards.
    • Maintenance and care: Check the wiring and operating status regularly, and deal with abnormalities in time. Clean the energy meter regularly to prevent dust from affecting operation.
    0.0 0
    Write your own review Close
    *
    *