Favorable price nitrogen gas tester for sale, measuring nitrogen content from 0 to 100% VoL, equipped with 4-20mA and RS485 signal output, using wall-mounted, pipeline and other installation methods. N2 gas detector is equipped with audible and visual alarms, suitable for 24-hour on-line monitoring and real-time display of data on a bright display, suitable for fixed installation, small size and easy to carry.
Specification
Model |
GD300-N2 |
Detection Principle |
Electrochemistry |
Gas |
Nitrogen (N2) |
Range |
0-100% VoL |
Resolution |
0.01% VoL |
Accuracy |
≤±3% F.S. |
Responce Time |
≤10s |
Repeatability |
≤±1% |
Recovery Time |
≤10s |
Linearity Error |
≤±1% |
Zero Shift |
≤±1% (F.S./year) |
Signal Output (Optional) Note |
4-20mA and RS485 Relay output: one group of relay output (1NO+1NC, 24V 100mA) for one alarm (default), or two groups of relay output (2NO+2NC, 24V 100mA) for high/low alarm (optional). |
Alarms |
Sound, light |
Display |
High light nixie tube display |
Installation |
Wall-mounted, piping type, flow-type (according to the detected environment) |
Connection |
G1/2 is the inlet and outlet for power and signal lines Pipe-mounted type: The installation thread size of the instrument is M45*P2.0 |
Operating Time |
24h |
Explosion-proof Grade |
Ex d llC T6 |
Protection Grade |
IP65 |
Certification |
CE, ATEX |
Working Voltage |
12~36V DC |
Case Material |
Die-casting aluminum housing |
Operating Temperature |
-20℃~50℃ |
Operating Humidity |
0~95%RH (non-condensing) |
Dimension |
206*179*90mm |
Weight |
≤1.6kg |
Accessories |
Power adapter: Input 100-240VAC 50/60Hz, Output 24VDC 2A (Optional USA plug & Europe plug) |
Fixed Gas Monitor User Manual
Gas Tester Functions
- This hydrogen gas detector adopts three-wire 4-20mA analog signal output, relay output, RS485 output (optional).
- The original imported sensors, with a unique infrared remote control function, non-contact operation and maintenance of hydrogen gas tester.
- Compatible with a variety of control alarms, PLC, DCS and other control systems, you can realize remote monitoring, gas monitoring is more accurate and reliable.
- Explosion-proof design grade is ExdlCT6, fast, credible and more stable.
- Full software auto-calibration function with temperature compensation can perfectly realize the compensation of gas concentration under different temperature environment.
Fixed N2 Gas Tester Details
Fixed Nitrogen Gas Tester with Alarm Dimension (Unit: mm)
Tips: Is the installation process of this nitrogen detector complicated?
The installation process is relatively simple, but should be completed by a qualified technician. Stationary nitrogen detectors usually need to be connected to a power supply and communication system and calibrated for the specific installation environment. Typically, the installation location should be in an area where nitrogen leaks are likely to be present and to ensure that the detector is able to cover the required detection range. A detailed installation guide is supplied with the gas detector to ensure correct wiring and mounting position so that the unit can optimally perform the monitoring task.