Select this chlorine (CL2) gas detector to add a safety barrier to your working environment. It has a variety of measurement ranges, from 0-10/20 ppm to 0-50/100 ppm, to meet the needs of different applications. Flexible output signals, optional 4-20mA and RS485, with one or two relay outputs, suitable for a variety of alarm settings. The device has passed the IP65 protection certification, which can withstand harsh environments.
Specification
Model |
GD300-CL2 |
Detected Gas |
Chlorine CL2 |
Measure Range |
0-10ppm, 0-20ppm, 0-50ppm, 0-100ppm |
Resolution |
0.01ppm (0-10/20/50ppm), 0.1ppm (0-100ppm) |
Install Method |
Wall-mounted, piping type, flow-type |
Output Signal (Optional) |
1. 4-20mA and RS485; 2. Relay outputone group of relay output (1NO+1NC, 24V 100mA) for one alarm (default), or two groups of relay output (2NO+2NC, 24V 100mA) for high/low alarm (optional). |
Precision |
≤±3%F.S. (higher precision is available) |
Zero Shift |
≤±1%(F.S./year) |
Display |
4 digits Nixie tube display. |
Connection Mode |
G1/2 is the inlet and outlet for power and signal lines; Pipe-mounted typeThe installation thread size of the instrument is M45*P2.0 |
Thread Size |
M45*2mm |
Temperature |
-20℃ ~ 50℃ |
Humidity |
0-95%RH (non-condensing) |
Explosion-Proof |
Ex dⅡCT6 |
Degree of Protection |
IP65 |
Alarm Mode |
Sound, light |
Material |
Case: Die-cast aluminum, Sensor housingaluminum alloy or 316 stainless steel |
Power |
12-36V DC |
Dimensions |
180×150×90mm |
Weight |
1.6kg |
Approval |
CE, ATEX |
Warranty |
12 months |
Fixed Gas Monitor User Manual
Gas Monitor Functions
- This chlorine gas detector adopts three-wire 4-20mA analog signal output, relay output, RS485 output (optional).
- The original imported sensors, with a unique infrared remote control function, non-contact operation and maintenance of hydrogen gas tester.
- Compatible with a variety of control alarms, PLC, DCS and other control systems, you can realize remote monitoring, gas monitoring is more accurate and reliable.
- Explosion-proof design grade is ExdlCT6, fast, credible and more stable.
- Full software auto-calibration function with temperature compensation can perfectly realize the compensation of gas concentration under different temperature environment.
Fixed CL2 Gas Monitor Details
Fixed Chlorine Gas Monitor with Alarm Dimension (Unit: mm)
Tips: What do I need to be aware of when using a fixed chlorine gas monitor?
When using a stationary chlorine gas detector, first ensure that the gas detector is installed in an area where there is a high risk of chlorine leakage, and regularly check and calibrate the device to ensure its sensitivity and accuracy. Also, avoid exposing the gas monitor to excessive moisture or corrosive environments to prevent damage to the sensor. Finally, review the monitoring data regularly to ensure timely response to alarm signals and a safe working environment.