Obtain the best grounding resistance tester with a measurement range of 0.010 Ω~1000 Ω, sound and color alarms, data memory, and online data retention. When using a grounding resistance meter to measure a loop grounding system, there is no need to disconnect the grounding lead and auxiliary grounding electrode, and non-contact measurement is safe and fast.
Details
The digital ground resistance tester is equipped with a 32mm clamp and has a measurement range of 0.010Ω~1000Ω.
- The sisco ground resistance meter is a major technological breakthrough in traditional ground resistance measurement. It is widely used in ground resistance measurement of power, telecommunications, meteorology, oil fields, construction, industry and electrical equipment.
- When measuring a grounding system with loop current, the digital ground resistance tester does not need to disconnect the ground wire or auxiliary electrodes. It is safe, fast and easy to use.

It is an insulation resistance tester equipped with double protection insulation.
- It is an insulation resistance tester that can measure faults that cannot be measured by traditional methods, can be applied in occasions that are not within the scope of traditional methods, and can also measure the comprehensive value of ground body resistance and ground wire resistance.
- The ground resistance meter is equipped with long claws, which is particularly suitable for flat steel grounding occasions. It is also able to measure leakage current and neutral point current in the grounding system.

This is the detailed display of each part of the clamp type ground resistance tester, ranging from 0.010 Ω to 1000 Ω.

Specifications
Model |
T-ERT-2000 |
Resistance Range |
0.010Ω~1000Ω |
Current Range |
- |
Clamp Size |
55mm×32mm |
Tester Size |
275mm×85mm×56mm |
Resistance Tester Weight |
2.3kg (including accessories) |
Power Supply |
6V DC ( 4 PCS of No.5 Alkaline dry batteries) |
LCD Screen |
4 Digits LCD display, 47mm×28.5mm |
Data Memory |
99 groups |
Alarm Function |
Yes |
Alarm Threshold Setting Range |
Resistance: 1-199Ω |
Operating Temperature and Humidity |
10℃ - 55℃, 10% RH - 90% RH |
Protection Class |
Double insulation |
Shift |
Automatically |
Accessories |
Resistance Tester: 1PCS; Test Ring: 1PCS; Instrument Case: 1PCS |
Clamp Meter Weight |
About 1130g (including battery) |
Resistance Measurement Accuracy
Range |
Resolution |
Accuracy |
0.010Ω-0.099Ω |
0.001Ω |
±(1%rdg+0.01Ω) |
0.10Ω-0.99Ω |
0.01Ω |
±(1%rdg+0.01Ω) |
1.0Ω-49.9Ω |
0.1Ω |
±(1%rdg+0.12) |
50.0Ω-99.5Ω |
0.5Ω |
±(1.5%rdg+0.5) |
100Ω-199Ω |
1Ω |
±(2%rdg+1Ω) |
200Ω-395Ω |
5Ω |
±(5%rdg+5Ω |
400-590Ω |
10Ω |
±(10%rdg+10Ω) |
600Ω-1100Ω |
20Ω |
±(20%rdg+20Ω) |
Tip: What is a clamp-on earth resistance tester?
The clamp-on earth resistance tester can measure the connection resistance of any looped system without using an auxiliary ground rod or interrupting the grounding of the equipment under test. As long as the ground wire or ground rod is clamped with the clamp head, the ground resistance can be measured safely and quickly. It can also be applied to multiple parallel grounding systems. The clamp-on ground resistance tester can measure the leakage current of 1MA, and the neutral line current can reach 20A. This function is especially important when the ground network to be tested contains large noise and harmonics.